bundle of composite vessels

Short description

Composite tanks (with a capacity of mostly 450 liter, 300 liter, 230 liter) are combined for a complete unit of maximum 10.800 liter. All advantages of CAFS Technology are available. The composite tanks are approved acc. PED 97/23/EC for a working pressure of max. 8 bar and a working temperature of 0 to +50 degrees celsius.

The propellant is compressed air, stored in the high pressure cylinders 200 bar. The pneumatic valves, used and established in many fire extinguishing systems, are controlling the system.

The core component of the system is the MicroCAFS mixing valve in which the compressed air foam will be produced by the patented mixing technology of MicroCAFS.

The significant difference to other extinguishing systems, in which only corresponding wetting or foam agents are dosed, is that there is no ambient air needed at the nozzles. The foam will be produced in the mixing valve by insertion of air and cannot be affected by external influences as for example fire smoke.

According to the efficiency of the patented mixing valve, a working pressure of up to 8 bar is sufficient.

The regulation for compressed air foam systems is EN 16327 (DIN 14430) and ISO 7076.

  • stand alone extinguishing unit
  • no external power supply
  • independent from water supply
  • almost all sizes can be combined by bundle of single vessels
  • less weight and less cost than stainless steel
  • even bigger units can be assembled in already existing buildings
  • quick assembly by premanufactured components

The activation of the system is triggered by a pressure loss in a detection tube / control tube. The pressure loss can be initiated by an electro-pneumatic valve or by hand release. The release valves controlling the detection tube are positioned on top of the high pressure cylinders.

The propellant air for the system gets into the vessel and the mixing valve by separate pressure reducer. The foam agent/water mixture is pressed through the discharge unit at the tank bottom into the mixing valve and mixed with the compressed air.

The patented mixing valve is designed according to the needed flow rate.

With the patented mixing technology it is not necessary to separate air support for discharging water/foam and CAFS mixing.

 

The ready mixed compressed air foam gets by distribution pipes to the sprinklers or nozzles.

pressure tanks:

150 – 10.800 liter composite vessels

air supply:

hp cylinders 200 bar or compressor

working pressure:

1 to max. 10 bar

flow rate:

standard up to 600 l/min. water/foam mix
optional up to 1.600 l/min. possible

temperature range:

min. 0°C up to max. + 50°C

release:

- automatically by sensor hose
- mechanically by hand valve
- electro-pneumatic valve by fire alert system

Special configurations according to customer requirements are possible.

 

The fire-extinguishing unit is a pressure equipment in accordance with  pressure equipment directive 97/23/EG.